Description
EASYDAN Storage Tanks
Engineered by Videira in DX 2205 stainless steel, Easydan cylinders are tailored for seamless pairing with Mitsubishi Electric heat pumps. They deliver high-efficiency domestic hot water through optimal heat transfer and premium energy savings, while ensuring outstanding reliability and long life.
The line covers single- or dual-coil versions, on-demand or buffer-ready models, suiting a wide range of requirements.
User benefits
- Thermal insulation: rigid CFC- and HCFC-free polyurethane foam, 50–60 mm thick.
- Outer shell in galvanised DX51 steel with electrostatic paint finish.
- Heat exchangers made of AISI 316L stainless steel.
- Built-in electric heating element.
- No magnesium anode needed.
- 7-bar safety hydraulic unit supplied.
| DHW capacity | 200 L | 300 L | ||||
| Model code | EASYDAN TT200-60 | EASYDAN TT300-90 | ||||
| Dimensions | Ø x Height | mm | 550 x 1980 | 550 x 2150 | ||
| Total capacity | L | 260 | 390 | |||
| DHW tank build | Duplex 2205 stainless steel | |||||
| Buffer tank material | AISI 316L stainless steel | |||||
| Instant HX surface | m² | 2.5 | 3.45 | 6.9 | 8.05 | |
| Instant HX volume | L | 15 | 18.2 | 32 | 37 | |
| Solar HX surface | 1.32 | 2.1 | 2.5 | 3.5 | ||
| Solar HX volume | 6 | 9.8 | 20.2 | 28.2 | ||
| Back-up heater | W / V | 2000 W / 230 V | 3000 W / 230 V | 10000 W / 400 V | 10000 W / 400 V | |
| Max. working pressure | 6 bar | |||||
| Max. operating temp. | ºC | 85 ºC | ||||
| Energy class | C | |||||
| Standing heat loss | W | 94 | 111 | 121 | 124 | |
| Insulation | 50 mm CFC-free blown PU | 100 mm flexible PU | ||||
| Outer casing | Electro-painted DX51D steel (RAL 9010) | PVC | ||||